Hello
The compressor is a variable speed and could be on high speed if your condenser is dirty. The condenser coils are at the top, behind the plastic control panel. Turn off the unit with the master switch behind the grille before you start cleaning. You have to remove the top grille by lifting and pulling out the center grille slat, which then exposes two 1/4 inch hex screws, which you remove to take off the whole grille. Then you can see two Phillips screws at the top of the plastic control panel, remove them and look behind the control panel to see two more 1/4 hex screws at the bottom of the control panel that each hold a small bracket keeping the bottom of the control panel in place. Loosen but do not remove them. Open both refrigerator doors, and pull the plastic control panel forward. There should be two cables that will support the panel, so just let it hang. Now you can see the black coils on the left side. Since the doors are still open (you cannot close them with the panel removed), you have to work quickly to clean the coils. Reassemble by placing the control panel back in place, taking care to get the bottom part under the brackets. Then tighten/reinstall all screws. DON'T FORGET TO TURN ON THE MASTER SWITCH WHEN YOU ARE DONE. See the complete manual link on your model below.
- AV Repair Help answered 2 years ago
Hello, we have attached the technical service manual for you. It has all troubleshooting diagnostics and steps to guide your process.
- Sam, Ace Appliance answered 2 years ago
- last active 2 years ago
Hello, there are 2 types of “ub” error codes for your washer. They are listed as “non-fatal” and as “fatal” unbalance errors and are listed as follows in the service manual for your model. 1st is Non-Fatal Unbalance Error : Machine has sensed load is unbalanced. Re-balance load and try spin step again. Do not adjust balance switch first. Most likely not due to unbalance switch mounting. If load is only one big item, add towels on opposite side to balance load. The 2nd is Fatal Unbalance Error : Wires to unbalance switch are broken or not connected. Switch may be stuck closed. Broken spring or unlevel machine causing tub to lean on unbalance switch. I have attached the complete service manual for you which contains all diagnostic steps and procedures for your model. I have also attached a link for your parts breakdown.
- Sam, Ace Appliance answered 2 years ago
- last active 2 years ago
Hi, sounds like you could have a communication issue between the main board and user interface. I have attached the service pointer for this. The U.I.and harness would need to be replaced since you already replaced the board. Also, check that power connections coming in at the junction box etc. are good, not loose or burnt that could cause power to drop out. Check the harness in the door between the U.I and main board for and broken, pinched wires. I have attached the service manual and tech sheet also.
- Brian, Ace Appliance answered 2 years ago
Hi. I could not find a video on this specific unit. I did find and attached the service manual. This has complete breakdown instructions. You will be able to access the control with the info in the manual.
- Brian, Ace Appliance answered 2 years ago
- last active 2 years ago
Yes, it would almost always be the board at this point if neither igniter is getting power. Very common on Frigidaire ovens. Make sure the board is getting 120v and that no wiring is damaged. Double check your model number. Its not showing as a good model number.
- Brian, Ace Appliance answered 2 years ago
Yes, it would almost always be the board at this point if neither igniter is getting power. Very common on Frigidaire ovens. Make sure the board is getting 120v and that no wiring is damaged. Double check your model number. Its not showing as a good model number.
- Brian, Ace Appliance answered 2 years ago
Hi. Temps in the freezer should 0-5 degrees and 32-45 in the refrigerator. I would take a look at the air damper to see if it is opening and closing properly. Also see if the damper on your unit is a electronic one. If not it will need to be replaced with one. P# WR13X10988. I also attached the mini manual for this unit.
- Brian, Ace Appliance answered 2 years ago
- last active 2 years ago
Hi. I have attached the service manual for this refrigerator. I would run the diagnostics in this manual if you have not already done so. See if there are any other errors codes. Also , the inverter board has a red LED on it that will indicate errors as well. You can check for proper voltage from the main board to the inverter. If voltage is correct you could have a bad inverter board. With what you have described, it does sound like the main board is faulty.
- Brian, Ace Appliance answered 2 years ago
Here is the service manual.
- AV Repair Help answered 2 years ago
Here is the service manual.
- AV Repair Help answered 2 years ago
Here is the service manual.
- AV Repair Help answered 2 years ago
Here is the service manual and tech sheet.
- AV Repair Help answered 2 years ago
Here is the service manual and tech sheet.
- AV Repair Help answered 2 years ago
Here is the service manual and tech sheet.
- AV Repair Help answered 2 years ago
Here is the service manual and tech sheet.
- AV Repair Help answered 2 years ago
Here is the service manual.
- AV Repair Help answered 2 years ago
Here is the service manual and tech sheet.
- AV Repair Help answered 2 years ago
Here is the service manual and tech sheet.
- AV Repair Help answered 2 years ago
Here is the service manual.
- AV Repair Help answered 2 years ago