Hello
From the symptoms you are explaining it sounds like you have a sealed system issue. A sealed system failure is one of two issues :
1) A refrigerant leak in the evaporator, condenser or existing tubing.
2) A compressor with a defective suction or discharge valve that is not pumping the refrigerant through the system.
To determine witch one of these possibilities a compressor or leak you would need to put refrigerant gages on the unit. I have provided a complete service manual for your product and the diagnostics start on page #69.