227 views

French door style fridge with freezer draw at bottom. fridge does not hold temperature (set for 32 but reads ~50F with separate thermometer). Initially, display at top (where doors close) displayed a “power outage” warning but there was no other indication that the house or that circuit had lost power at anytime. made several attempts to turn power off to fridge (at the breaker) with hope it would reset. fridge makes several different types of audible chimes, sometimes with two distinctly different chines going off at the same time. I have not been able to find anything on the internet to help put this specific model into diagnostic mode, nor do i have the cheat sheet to know what those codes mean but suspect switches at the ice dispenser console (exterior of left door) can get me into diagnostic mode. Also, i will occasionally hear a mechanical whine (very low) which could be compressor related. everything else about the failure and various chimes (one could be a high temp warning) suggests possible bad control board or power supply tripping an issue? Bottomline, would like to diagnose the problem, understand what part(s) are required to fix it and get repair instructions to swap out that part.

0 votes
198 views

Please provide a Trch Service Manual.
Unit Works on Everything except won’t spin.

  • mikjanes asked 2 months ago
  • last active 2 months ago
0 votes
422 views

I AM GETTING WATER DISPENSING AT THE DOOR. HOWEVER I AM NOT GETTING WATER TO ICE MAKER. I HAVE REPLACED MOTHER BOARD. MAIN. AND THE WATER AND ICE BOARD. AND WATER INLET VALVES.

0 votes
250 views

Hi i need to replace the motor pump but i didnt find a video that shows how to do it thank you
this is the part number: WD19X24705

0 votes
301 views

Washer is getting H2O error code washer is not getting cold water water valve has already been replaced solenoid good on Coldwater valve not getting 120 VAC To cold water valve I put washer and diagnostics mode test number seven no cold water comes in Solenoid is not energized not sure if it’s The main PCB board need service manual for washer Hot water valve and other valves are working properly

  • Loinest76 asked 4 months ago
  • last active 4 months ago
0 votes
359 views

Top load washer show error code 8C. Not sure what “Check detected in the Mems PBA or data Check detected” and “PBA’s silver nano” mean.

0 votes
358 views

Dishwasher has power, Programming lights function , fills with water but does nothing else unless you push cancel button and then drains out water

  • mikjanes asked 6 months ago
  • last active 6 months ago
0 votes
406 views

GOOD DAY,
WE HAVE A GE REFRIGERATOR THAT EVERY MONTH OR 2 THE DRAIN LINE FREEZES AND NEEDS TO BE CLEARED. NOW THE REFER SIDE IS TOO COLD AND FREEZING THE VEGES AS WELL AS THE DRAIN TUBE BLOCKED AGAIN.

THANK YOU,
LISA MARTIN

0 votes
348 views

Whirlpool fridge randomly displays two negative signs. One negative sign on the FZ display and one negative sign on the FF display. When this happens the refrigerator stops cooling both compartments. User Interface buttons need to be press and that makes the refrigerator work again. Once the refrigerator is working normally it takes a couple of days for the negative signs to pop up again.

0 votes
349 views

This is for a GE range.

0 votes
549 views

This client of ours is re-reporting their side-by-side refrigerator refrigerator keeps going into overheat and displays that on the front display. Resident and unplugged it and turns it back on and it’s working properly. This continues to happen more and more for our resident. Is there a part that I need to replace to prevent this, every time I go there, the refrigerator is working properly.

0 votes
454 views

Want to know if you can provide me the techsheet and your opinion on what this issue could be? Thanks!

0 votes
390 views

The code is telling me the the cold side of the water inlet valve is letting it spin.

  • Scales asked 7 months ago
  • last active 7 months ago
0 votes
599 views

Thermador: This unit is eventually getting to temp but it is taking a long time. This Bake will turn on for 10 seconds then turn off, then turn on again until it eventually gets to temp but it takes a really long time.

0 votes
677 views

Can you send me a video on how to replace a spider bracket for a front load wahser?

0 votes
814 views

Machine does not complete cycle – no spin

  • kmisch asked 10 months ago
  • last active 10 months ago
0 votes
667 views

Problem when spinning make a lot noise whirlpool washer

  • Juanbolanos asked 10 months ago
  • last active 10 months ago
0 votes
721 views

Please me help

  • Juanbolanos asked 10 months ago
  • last active 10 months ago
0 votes
531 views

Customer complaint before arrival is washer will not spin the clothes out at the end of the cycle. Homeowner did advise that it will only work on bulky cycle technician arrived. Had an F5 E2 code door lock assembly error. We replace that unit is still not spinning out on any other cycle, except for bulky, when we came back out, we went to retrieve the error codes and there was none in there ran a cycle on normal and it does not spin out the clothes. You can turn it to drain and spin and it will spin out the clothes properly also, the drain is working properly too , not quite sure where to go with this any help would be appreciated Please email me if you need more information or need anything. Thank you, Daniel Woods.

  • dwoods asked 10 months ago
  • last active 10 months ago
0 votes
655 views

washer is not draining, but I just replaced the pump 2 yrs ago, the pump seems to have proper resistance, touching it through the filter hole.
I recall the flapper can be a problem , it’s a rubber check valve . Is it possible a hot steam cycle made is flexible enough to push through and cause problems with all cycles? it started on steam cycle, now all cycles won’t drain. I thought i would ask you guys before I go to the trouble on this .

also I know your 29.00 only co=vers one appliance , but I just need a recommendation, matching dryer dv448gp/xaa is a bit noisy, do you guys recommend replacing the springs and wheels around the drum, or should I wait till some happens?

  • Bluewasher asked 11 months ago
  • last active 10 months ago
0 votes
612 views

I have a service call tomorrow for a refrigerator not dispensing ice. It does dispense water, icemaker is making ice the only issue customer said is not dispensing ice.

0 votes
725 views
  • Guest asked 12 months ago
  • last active 12 months ago
0 votes
567 views
  • mikjanes asked 12 months ago
  • last active 12 months ago
0 votes
774 views

Not spining

  • Juanbolanos asked 12 months ago
  • last active 12 months ago
0 votes
779 views

It had the compressor replaced about 3 years ago, I can fill it running but my gauges won’t work I guess it is because it is a flamable refrigerant. the condensor and evaporator fans are running. I replaced the thermister on the compressor but it didn’t help Idon’t know how to test the other components. It has a small computer on the top but I couldn’t find a way to test the other components.

  • Guest asked 1 year ago
  • last active 1 year ago
0 votes
737 views

My technician changed two infinite switches on a radiant cooktop.

The part that was changed is 700855K. Issue is that the two right side burners, after connection, control each other’s heat level. Burners turn on independently and the issue with heat control is only applicable if both burners are operating simultaneously.

Could you provide guidance on proper wiring instructions for these switches? My thought is that the technician did the wiring incorrectly. The old switch for reference is part# 203147. The confusion lies in a difference for terminal markings between the old switch (203147) and new switch (700855K).

I’m the owner, but not a technician. Please let me know if there is a bulletin or supporting document for the issue.

Thank you,
Greg Bahry
832-656-9034

  • gregoryb7 asked 1 year ago
  • last active 1 year ago
0 votes
758 views

I have a 10 Year old Speed Queen dryer. I watched your video for replacing the timer a D517560 but my dryer does not have the connectors it just has the separate wires with the little clips on the end. Where do the 2 black wires from – it looks like the timer go. One goes to the T connector but I need to know where the other one terminates.

  • Guest asked 1 year ago
  • last active 1 year ago
1 vote
627 views

watched your video, ordered a new capacitor and relay module. Installed new unit same issue. Any other solutions? Refrigerator is only 13 months old.

  • Guest asked 1 year ago
  • last active 1 year ago
0 votes
677 views

Refrigerator is cooling ok but freezer is 51 f

  • Guest asked 1 year ago
  • last active 1 year ago
0 votes
661 views

The condenser for this combo needs to be changed due to moisture not being removed. I would like to know if there are any videos for this model as its a never version. Need any tips on assembly for this part.

  • GeekJames asked 1 year ago
  • last active 1 year ago